Products & Portfolio

Analyzer In-market
Exdia TRF Plus

Exdia TRF
Under Development
Multichannel
  • · Non-sequential mode
  • · Independent measurement
  • · Immunoassay analyzer with TRF technology

All New POCT
  • · Liquid-type cartridge
  • · Temperature control
  • · Automated sample processing

Mobile Diagnosis
  • · Mobile platform
  • · Simultaneous measurement of Fluorescence / Absorbance
  • · Test results and location data transfer via 4G/5G network
Cardiac Infection Brain Others
Cartridge In-market NT-proBNP
(Heart failure)
Troponin I
(Myocardial infarction)
D-dimer
(Cardiovascular disease)
3-in-1
(TnI/Myo/CK-MB)
Influenza A+B
(Influenza)
PCT
(Bacterial infection)
CRP
(Inflammation)
COVID-19
(SARS-CoV-2)
iFOB
(Colorectal disorder)
ß-hCG
(Pregnancy)
Vitamin D
(Vitamin D deficiency)
Under Development SOB
(Shortness of breath)
Norovirus
(Acute gastroenteritis)
Tuberculosis
Strep A
(Respiratory inflammation)
CRE
(Carbapenem-resistant enterobacteriaceae)
mTBI
(Traumatic brain injury)
Stroke
(Ischemic/Hemorrhagic stroke)
TSH
(Thyroid stimulating hormone)
T3/T4
(Thyroid function)

Cartridge

In-market

Under Development


Multichannel
  • · Non-sequential mode
  • · Independent measurement
  • · Immunoassay analyzer with TRF technology

All New POCT
  • · Liquid-type cartridge
  • · Temperature control
  • · Automated sample processing

Mobile Diagnosis
  • · Mobile platform
  • · Simultaneous measurement of Fluorescence / Absorbance
  • · Test results and location data transfer via 4G/5G network
Cartridge
In-market
Cardiac NT-proBNP
(Heart failure)
Troponin I
(Myocardial infarction)
D-dimer
(Cardiovascular disease)
3-in-1
(TnI/Myo/CK-MB)
Infection Influenza A+B
(Influenza)
PCT
(Bacterial infection)
CRP
(Inflammation)
COVID-19
(SARS-CoV-2)
Brain
Others iFOB
(Colorectal Disorder)
ß-hCG
(Pregnancy)
Vitamin D
(Vitamin D deficiency)
Under Development
Cardiac SOB
(Shortness of breath)
Infection Norovirus
(Acute gastroenteritis)
Tuberculosis

Strep A
(Respiratory inflammation)
CRE
(Carbapenem-resistant enterobacteriaceae)
Brain mTBI
(Traumatic brain injury)
Stroke
(Ischemic/Hemorrhagic stroke)
Others TSH
(Thyroid stimulating hormone)
T3/T4
(Thyroid function)
Cartridge
Cardiac
  • Exdia NT-proBNP
    • Product Code PR-FC02
    • Sample type Whole blood, Plasma, Serum
    • Sample Volume 80 μL
    • Measuring Time 15min
    • Measuring Range 20-12,000 pg/mL
    • Certificate CE, MFDS
    One–step quantitative Time-Resolved Fluorescence immuno-chromatography assay for the detection of NT-proBNP (N-terminal pro-brain natriuretic peptide) in human whole blood, serum and plasma as an aid in early diagnosis of individuals suspected of having CHF (congestive heart failure).
  • Exdia Troponin I
    • Product Code PR-FC01
    • Sample type Whole blood, Plasma, Serum
    • Sample Volume 80 μL
    • Measuring Time 15min
    • Measuring Range 0.03-30 ng/mL
    • Certificate CE, MFDS
    One–step quantitative Time-Resolved Fluorescence immuno-chromatography assay for the detection of TnI (Troponin I) in human whole blood, serum and plasma as an aid in early diagnosis of AMI (acute myocardial infarction) and cardiac muscle damage.
  • Exdia D-dimer
    • Product Code PR-FC03
    • Sample type Whole blood, Plasma
    • Sample Volume 10 μL (WB),
      5 μL (Plasma),
      80 μL (On going)
    • Measuring Time 15min
    • Measuring Range 120-4,400 ng/mL
    • Certificate CE, MFDS
    One–step quantitative Time-Resolved Fluorescence immuno-chromatography assay for the detection of D-dimer in human whole blood and plasma as an aid in early diagnosis of DIC (disseminated intravascular coagulation) and VTE (venous thromboembolism).
  • Exdia 3-in-1(TnI, CK-MB, Myo)
    • Product Code PR-FC04
    • Sample type Whole blood, Plasma, Serum
    • Sample Volume 80 μL
    • Measuring Time 15min
    • Measuring Range TnI: 0.03-30 ng/mL
      CK-MB: 2-200 ng/mL
      Myo: 10-500 ng/mL
    • Certificate CE, MFDS (Export only)
    One–step quantitative Time-Resolved Fluorescence immuno-chromatography assay for the detection of TnI (Troponin I), CK-MB (creatine kinase MB) and Myoglobin in human whole blood, serum and plasma as an aid in diagnosis of AMI (acute myocardial infarction).
Infection
  • Exdia Influenza A+B
    • Product Code PR-FC09
    • Sample type Nasopharyngeal swab
    • Sample Volume -
    • Measuring Time 10min
    • Measuring Range -
    • Certificate CE, MFDS
    One–step qualitative Time-Resolved Fluorescence immuno-chromatography assay for the detection of influenza A and B in human nasopharyngeal secretion as an aid in the rapid differential diagnosis of influenza A and influenza B viral infections.
  • Exdia PCT
    • Product Code PR-FC05
    • Sample type Whole blood, Plasma, Serum
    • Sample Volume 20 μL(WB),
      10 μL(Plasma, Serum)
    • Measuring Time 15min
    • Measuring Range 0.07-30 ng/mL
    • Certificate CE, MFDS
    One–step quantitative Time-Resolved Fluorescence immuno-chromatography assay for the detection of PCT (procalcitonin) in human whole blood, serum and plasma as an aid in early diagnosis of systemic or severe bacterial infection and sepsis.
  • Exdia CRP
    • Product Code PR-FC06
    • Sample type Whole blood, Plasma, Serum
    • Sample Volume 2 μL
    • Measuring Time 5min
    • Measuring Range 0.1-150 μg/mL
    • Certificate CE, MFDS (Export only)
    One–step quantitative Time-Resolved Fluorescence immuno-chromatography assay for the detection of CRP (c-reactive protein) in human whole blood, serum and plasma as an aid in the detection and evaluation of infection, tissue injury, inflammation and associated diseases.
  • Exdia COVID-19 IgG/IgM
    • Product Code PR-FC12
    • Sample type Whole blood, Plasma, Serum
    • Sample Volume 10 μL (WB),
      5 μL (Plasma, Serum)
    • Measuring Time 15min
    • Measuring Range -
    • Certificate CE, MFDS (Export only)
    One–step high-sensitive Time-Resolved Fluorescence immuno-chromatography assay for the qualitative detection of human IgG/IgM antibodies to SARS-CoV-2 in human whole blood, serum and plasma as an aid in identifying individuals with an adaptive immune response to SARS-CoV-2, indicating recent or prior infection.
  • PBCheck COVID-19 IgG/IgM
    • Product Code PR-GC01
    • Sample type Whole blood, Plasma, Serum
    • Sample Volume 10 μL (WB),
      5 μL (Plasma, Serum)
    • Measuring Time 10min
    • Measuring Range -
    • Certificate CE, MFDS (Export only)
    One–step rapid immunoassay for the qualitative detection of human IgG/IgM antibodies to SARS-CoV-2 in human whole blood, serum and plasma as an aid in identifying individuals with an adaptive immune response to SARS-CoV-2, indicating recent or prior infection.
  • Exdia COVID-19 Ag
    • Product Code PR-FC13
    • Sample type Nasopharyngeal Swab
    • Sample Volume 70~90 μl
    • Measuring Time 20min
    • Measuring Range -
    • Certificate CE, MFDS (Export only)
    One-step high-sensitive Time-Resolved Fluorescence immuno-chromatography assay that is used with Exdia TRF analyzer for the qualitative detection of SARS-CoV-2 antigen in human nasopharyngeal secretion as an aid in identifying individuals who are suspected of COVID-19 infection.
  • PBCheck COVID-19 Ag
    • Product Code PR-GC02
    • Sample type Nasopharyngeal Swab
    • Sample Volume 70~90 μl
    • Measuring Time 10min
    • Measuring Range -
    • Certificate CE, MFDS (Export only)
    One-step rapid immunoassay for the qualitative detection of SARS-CoV-2 antigen in human nasopharyngeal secretion as an aid in identifying individuals who are suspected of COVID-19 infection.
Others
  • Exdia iFOB
    • Product Code PR-FC07
    • Sample type Stool
    • Sample Volume -
    • Measuring Time 5min
    • Measuring Range 25-1,000 ng/mL,
      5-200 μg/g
    • Certificate CE, MFDS
    One–step qualitative Time-Resolved Fluorescence immuno-chromatography assay for the detection of fecal occult blood in human feces as an aid in the diagnosis of lower gastrointestinal disorders such as suspected colorectal cancer and gastrointestinal bleeding.
  • Exdia β-hCG
    • Product Code PR-FC10
    • Sample type Whole blood, Plasma
    • Sample Volume 80 μL
    • Measuring Time 10min
    • Measuring Range 2-500 mIU/mL
    • Certificate CE, MFDS
    One–step quantitative Time-Resolved Fluorescence immuno-chromatography assay for the detection of β-hCG (beta-human chorionic gonadotropin) in human whole blood and plasma as an aid in the early detection of pregnancy.
  • Exdia Vitamin D
    • Product Code PR-FC11
    • Sample type Plasma, Serum
    • Sample Volume 80 μL
    • Measuring Time 25min
    • Measuring Range 8.4-100 ng/mL
    • Certificate CE, MFDS
    One–step quantitative Time-Resolved Fluorescence immuno-chromatography assay for the detection of vitamin D (total 25(OH)D2/D3) in human serum and plasma as an aid in the assessment of vitamin D sufficiency.
Analyzer
Exdia TRF Plus
  • Introduction
    Exdia TRF Plus is an image-based immunochromatographic analyzer with TRF analysis technology which provides qualitative and quantitative test results.
    Exdia TRF Plus can be used with Exdia cartridges to analyze specific in vitro samples in human specimens.
    Using the built-in printer and data management software, all test results can be printed or sent to a laboratory or hospital information system to manage the results.
    Intuitive and user-friendly graphical user interface (GUI) with the wide 7-inch color LCD touchscreen makes the analyzer easy to operate.
Exdia TRF
  • Introduction
    Exdia TRF is an image-based immunochromatographic analyzer with TRF analysis technology which provides qualitative and quantitative test results.
    Exdia TRF can be used with Exdia cartridges to analyze specific in vitro samples in human specimens.
    Using the data management software, all test results can be sent to a laboratory or hospital information system to manage the results.
    Intuitive and user-friendly graphical user interface (GUI) with the wide 7-inch color LCD touchscreen makes the analyzer easy to operate.
Accessory
Exdia Heating Block
  • Introduction
    As a thermostat device for activating the reagent reactions, Heating Block enables precise temperature control through digital control and is user-friendly.
    It is suitable to be used in various experimental environments by applying debugging using serial ports and firmware update functions, as well as timer functions for individual tube rack.
Exdia IQC
  • Introduction
    To measure the concentration of the Exdia IQC, the tested cartridge must be read by Exdia TRF (Plus) Analyzer.
    The Analyzer analyzes the strength of the three test lines on IQC Cassette and converts them into values.
    The converted values are then calculated as a percentage of each line, which is further compared to the previously-set reference ratio.
    If the value is within the acceptable range, the performance of the Exdia TRF (Plus) can be confirmed to be stable.